{"id":99,"date":"2023-02-10T16:05:03","date_gmt":"2023-02-10T16:05:03","guid":{"rendered":"https:\/\/www.atommed.net\/atomtest1\/?p=99"},"modified":"2023-03-19T22:17:57","modified_gmt":"2023-03-19T22:17:57","slug":"selectra-pro-xl","status":"publish","type":"post","link":"https:\/\/www.atommed.net\/web\/2023\/02\/10\/selectra-pro-xl\/","title":{"rendered":"Selectra ProXL"},"content":{"rendered":"<div class=\"fusion-li-item-content\"><\/p>\n<p dir=\"ltr\"><strong>Shpejt\u00ebsia e leximit<\/strong>: 450 teste me ISE dhe 360 teste pa ISE<\/p>\n<\/div>\n<div class=\"fusion-li-item-content\"><\/p>\n<p dir=\"ltr\"><strong>Numri i depove<\/strong>: 64 vendndodhje t\u00eb reagent\u00ebve n\u00eb dy tabaka, t\u00eb p\u00ebrdorura n\u00eb shishe Cc10 \u2013 Cc25 dhe CC50 t\u00eb pajisura me sistem ftohjeje | Mund\u00ebsia p\u00ebr t\u00eb p\u00ebrdorur cilindo nga stacionet si reagent\u00eb R3-R2-R1<\/p>\n<\/div>\n<div class=\"fusion-li-item-content\">\n<p dir=\"ltr\"><strong>Sistemi i marrjes s\u00eb mostrave t\u00eb reagentit dhe mostra:<\/strong> Dy shiringa prej 1000 \u03bcl p\u00ebr grumbullimin e reagent\u00ebve dhe dy shiringa 100 \u03bcl p\u00ebr mbledhjen e mostr\u00ebs. V\u00ebllimi i l\u00ebvizsh\u00ebm prej 400-110 \u03bcl p\u00ebr R1 dhe v\u00ebllimi i l\u00ebvizsh\u00ebm \u03bcL 180 p\u00ebr R2 dhe R3 me nj\u00eb kapacitet vjeljeje \u03bcl 1, v\u00ebllimi i kampionit 30 \u03bcl me aft\u00ebsi nxjerrjeje 0,1 \u03bcl, gjilp\u00ebra e reagentit e pajisur me nj\u00eb ngroh\u00ebs fillestar. <br \/>P\u00ebr t\u00eb parandaluar kontaminimin e reagent\u00ebve dhe mostrave, gjilp\u00ebrat e recet\u00ebs jan\u00eb t\u00eb pajisura me nj\u00eb sensor sip\u00ebrfaq\u00ebsor dhe prania e sistemit lejon zbulimin e v\u00ebllimit n\u00eb shishet e referenc\u00ebs. Gjilp\u00ebrat e reagentit dhe mostr\u00ebs, p\u00ebrve\u00e7 sensorit t\u00eb sip\u00ebrfaqes, jan\u00eb t\u00eb pajisura me nj\u00eb sensor p\u00ebrplasjeje.<\/p>\n<\/div>\n<div class=\"fusion-li-item-content\">\n<p dir=\"ltr\"><strong>Tabakja e reagimit (Kuveta)<\/strong>: Me dy tabaka t\u00eb ve\u00e7anta reagimi, secila tabaka ka 48 kuveta nd\u00ebrlidh\u00ebse, me sistem larjeje t\u00eb plot\u00eb automatike. <br \/>Sistemi i elementeve Peltier ka nj\u00eb temperatur\u00eb prej 37 \u00b0 C (\u00b1 0,1 \u00b0 C)<\/p>\n<\/div>\n<div class=\"fusion-li-item-content\">\n<p dir=\"ltr\"><strong>Sistemi optik<\/strong>: Llamb\u00eb halogjene 12V 20V Dy sisteme t\u00eb ve\u00e7anta optike kan\u00eb secili 8 filtra optik\u00eb me gjat\u00ebsi vale 340 \u2013 405 \u2013 505 \u2013 546 \u2013 578 \u2013 620 \u2013 660 dhe 700 nm, secila \u00ebsht\u00eb e k\u00ebmbyeshme.<\/p>\n<\/div>\n<div class=\"fusion-li-item-content\">\n<p dir=\"ltr\"><strong>Vuajtje fotometrike<\/strong>: Vuajtje fotometrike lineare -0.1-3.0 me nj\u00eb sakt\u00ebsi prej 0.001 Abs<\/p>\n<\/div>\n<div class=\"fusion-li-item-content\">\n<p dir=\"ltr\"><strong>Metodat e leximit:<\/strong> Aft\u00ebsia p\u00ebr t\u00eb matur me pik\u00ebn p\u00ebrfundimtare biokromatike dhe dy pika kinetike, pik\u00ebn fundore, aft\u00ebsia p\u00ebr t\u00eb grafikuar reaksionin e hollimit automatik t\u00eb reaksionit t\u00eb ekzemplar\u00ebve t\u00eb ve\u00e7ant\u00eb (mostrat p\u00ebrqendrimet e t\u00eb cilave tejkalojn\u00eb leximet e linj\u00ebs s\u00eb kompletit). Kryeni nj\u00eb kalibrim t\u00eb nj\u00eb Pike dhe shum\u00ebpik\u00ebshe (p\u00ebr testet kurbat e t\u00eb cilave jan\u00eb form\u00ebsuar si p\u00ebrgjigje) Prozone Check p\u00ebr testim imunitar me funksionalitetin CUT OFF dhe llogarit boshll\u00ebkun e reagentit dhe llogaritjet e mostr\u00ebs bosh n\u00ebse \u00ebsht\u00eb e nevojshme.<\/p>\n<\/div>\n<div class=\"fusion-li-item-content\">\n<p dir=\"ltr\"><strong>Kontrolli i cil\u00ebsis\u00eb:<\/strong> aft\u00ebsia p\u00ebr t\u00eb p\u00ebrcaktuar 15 kontrolle t\u00eb ndryshme dhe mund\u00ebsia e vendosjes s\u00eb 3 kontrolleve p\u00ebr nj\u00eb test mujor t\u00eb grafik\u00ebve t\u00eb kontrollit t\u00eb cil\u00ebsis\u00eb dhe zbatimi i rregullave t\u00eb westgard<\/p>\n<\/div>\n<div class=\"fusion-li-item-content\">\n<p dir=\"ltr\"><strong>Standardet:<\/strong> CB, CE-IVD dhe UL<\/p>\n<\/div>\n<div class=\"fusion-li-item-content\">\n<p dir=\"ltr\"><strong>Specifikimet dhe softueri i kompjuterit:<\/strong> PC me ekran me prekje, softueri Windows XP MS i p\u00ebrfshir\u00eb me dalje RS232 (rrjet)<\/p>\n<\/div>\n<div class=\"fusion-li-item-content\">\n<p dir=\"ltr\"><strong>Konsumimi i energjis\u00eb dhe specifikimet mjedisore dhe konsumi i ujit t\u00eb distiluar<\/strong>: Vac 240-100 volt dhe konsumi maksimal i energjis\u00eb VA 1K Frekuenca 60-50 Hz Mund t\u00eb p\u00ebrdoret n\u00eb temperatur\u00ebn e ambientit 15- 15 \u00b0 C dhe lag\u00ebshtia 15-88% Uj\u00eb i distiluar 1 lit\u00ebr n\u00eb or\u00eb<\/p>\n<\/div>\n<div class=\"fusion-li-item-content\">\n<p dir=\"ltr\"><strong>Shtes\u00eb<\/strong>: (Sipas porosis\u00eb dhe nuk disponohet me pajisjen) Lexues bar kodi Izolimi i uj\u00ebrave t\u00eb zeza t\u00eb holluara dhe t\u00eb trasha | ISE p\u00ebr matjen e Kalium-natrium-Klorurit dhe Co2 | Printer<\/p>\n<\/div>\n<div class=\"fusion-li-item-content\">\n<p dir=\"ltr\"><strong>Dimensionet dhe pesha e pajisjes<\/strong>: gjat\u00ebsia 117 cm, gjer\u00ebsia 80 cm, lart\u00ebsia 115 cm, pesha 190 kg<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Shpejt\u00ebsia e leximit: 450 teste me ISE dhe 360 teste pa ISE Numri i depove: 64 vendndodhje t\u00eb reagent\u00ebve n\u00eb dy tabaka, t\u00eb p\u00ebrdorura n\u00eb shishe Cc10 \u2013 Cc25 dhe CC50 t\u00eb pajisura me sistem ftohjeje | Mund\u00ebsia p\u00ebr t\u00eb p\u00ebrdorur cilindo nga stacionet si reagent\u00eb R3-R2-R1 Sistemi i marrjes s\u00eb mostrave t\u00eb reagentit dhe mostra: Dy shiringa prej 1000 \u03bcl p\u00ebr grumbullimin e reagent\u00ebve dhe dy shiringa 100 \u03bcl p\u00ebr mbledhjen e mostr\u00ebs. V\u00ebllimi i l\u00ebvizsh\u00ebm prej 400-110 \u03bcl p\u00ebr R1 dhe v\u00ebllimi i l\u00ebvizsh\u00ebm \u03bcL 180 p\u00ebr R2 dhe R3 me nj\u00eb kapacitet vjeljeje \u03bcl 1, v\u00ebllimi i kampionit 30 \u03bcl me aft\u00ebsi nxjerrjeje 0,1 \u03bcl, gjilp\u00ebra e reagentit e pajisur me nj\u00eb ngroh\u00ebs fillestar. P\u00ebr t\u00eb parandaluar kontaminimin e reagent\u00ebve dhe mostrave, gjilp\u00ebrat e recet\u00ebs jan\u00eb t\u00eb pajisura me nj\u00eb sensor sip\u00ebrfaq\u00ebsor dhe prania e sistemit lejon zbulimin e v\u00ebllimit n\u00eb shishet e referenc\u00ebs. Gjilp\u00ebrat e reagentit dhe mostr\u00ebs, p\u00ebrve\u00e7 sensorit t\u00eb sip\u00ebrfaqes, jan\u00eb t\u00eb pajisura me nj\u00eb sensor p\u00ebrplasjeje. Tabakja e reagimit (Kuveta): Me dy tabaka t\u00eb ve\u00e7anta reagimi, secila tabaka ka 48 kuveta nd\u00ebrlidh\u00ebse, me sistem larjeje t\u00eb plot\u00eb automatike. Sistemi i elementeve Peltier ka nj\u00eb temperatur\u00eb prej 37 \u00b0 C (\u00b1 0,1 \u00b0 C) Sistemi optik: Llamb\u00eb halogjene 12V 20V Dy sisteme t\u00eb ve\u00e7anta optike kan\u00eb secili 8 filtra optik\u00eb me gjat\u00ebsi vale 340 \u2013 405 \u2013 505 \u2013 546 \u2013 578 \u2013 620 \u2013 660 dhe 700 nm, secila \u00ebsht\u00eb e k\u00ebmbyeshme. Vuajtje fotometrike: Vuajtje fotometrike lineare -0.1-3.0 me nj\u00eb sakt\u00ebsi prej 0.001 Abs Metodat e leximit: Aft\u00ebsia p\u00ebr t\u00eb matur me pik\u00ebn p\u00ebrfundimtare biokromatike dhe dy pika kinetike, pik\u00ebn fundore, aft\u00ebsia p\u00ebr t\u00eb grafikuar reaksionin e hollimit automatik t\u00eb reaksionit t\u00eb ekzemplar\u00ebve t\u00eb ve\u00e7ant\u00eb (mostrat p\u00ebrqendrimet e t\u00eb cilave tejkalojn\u00eb leximet e linj\u00ebs s\u00eb kompletit). Kryeni nj\u00eb kalibrim t\u00eb nj\u00eb Pike dhe shum\u00ebpik\u00ebshe (p\u00ebr testet kurbat e t\u00eb cilave jan\u00eb form\u00ebsuar si p\u00ebrgjigje) Prozone Check p\u00ebr testim imunitar me funksionalitetin CUT OFF dhe llogarit boshll\u00ebkun e reagentit dhe llogaritjet e mostr\u00ebs bosh n\u00ebse \u00ebsht\u00eb e nevojshme. Kontrolli i cil\u00ebsis\u00eb: aft\u00ebsia p\u00ebr t\u00eb p\u00ebrcaktuar 15 kontrolle t\u00eb ndryshme dhe mund\u00ebsia e vendosjes s\u00eb 3 kontrolleve p\u00ebr nj\u00eb test mujor t\u00eb grafik\u00ebve t\u00eb kontrollit t\u00eb cil\u00ebsis\u00eb dhe zbatimi i rregullave t\u00eb westgard Standardet: CB, CE-IVD dhe UL Specifikimet dhe softueri i kompjuterit: PC me ekran me prekje, softueri Windows XP MS i p\u00ebrfshir\u00eb me dalje RS232 (rrjet) Konsumimi i energjis\u00eb dhe specifikimet mjedisore dhe konsumi i ujit t\u00eb distiluar: Vac 240-100 volt dhe konsumi maksimal i energjis\u00eb VA 1K Frekuenca 60-50 Hz Mund t\u00eb p\u00ebrdoret n\u00eb temperatur\u00ebn e ambientit 15- 15 \u00b0 C dhe lag\u00ebshtia 15-88% Uj\u00eb i distiluar 1 lit\u00ebr n\u00eb or\u00eb Shtes\u00eb: (Sipas porosis\u00eb dhe nuk disponohet me pajisjen) Lexues bar kodi Izolimi i uj\u00ebrave t\u00eb zeza t\u00eb holluara dhe t\u00eb trasha | ISE p\u00ebr matjen e Kalium-natrium-Klorurit dhe Co2 | Printer Dimensionet dhe pesha e pajisjes: gjat\u00ebsia 117 cm, gjer\u00ebsia 80 cm, lart\u00ebsia 115 cm, pesha 190 kg<\/p>\n","protected":false},"author":1,"featured_media":1039,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-99","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-selectra"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.atommed.net\/web\/wp-json\/wp\/v2\/posts\/99","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.atommed.net\/web\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.atommed.net\/web\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.atommed.net\/web\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.atommed.net\/web\/wp-json\/wp\/v2\/comments?post=99"}],"version-history":[{"count":10,"href":"https:\/\/www.atommed.net\/web\/wp-json\/wp\/v2\/posts\/99\/revisions"}],"predecessor-version":[{"id":1136,"href":"https:\/\/www.atommed.net\/web\/wp-json\/wp\/v2\/posts\/99\/revisions\/1136"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.atommed.net\/web\/wp-json\/wp\/v2\/media\/1039"}],"wp:attachment":[{"href":"https:\/\/www.atommed.net\/web\/wp-json\/wp\/v2\/media?parent=99"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.atommed.net\/web\/wp-json\/wp\/v2\/categories?post=99"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.atommed.net\/web\/wp-json\/wp\/v2\/tags?post=99"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}