{"id":334,"date":"2023-02-16T09:45:30","date_gmt":"2023-02-16T09:45:30","guid":{"rendered":"https:\/\/www.atommed.net\/atomtest1\/?p=334"},"modified":"2023-03-14T14:57:33","modified_gmt":"2023-03-14T14:57:33","slug":"hipro-a3","status":"publish","type":"post","link":"https:\/\/www.atommed.net\/web\/en\/2023\/02\/16\/hipro-a3\/","title":{"rendered":"Hipro A3"},"content":{"rendered":"<p>Three tests within 360 seconds<br \/>\nmaximum<\/p>\n<p>Principle and Implementation<br \/>\nIt is based on the specific reaction of antigen and antibodies. The reaction reaction will occur as a combination of antigen and antibodies, thus enhancing the value of the distribution of light\/ absorption\/ fluorescence. Assuming that the concentration of antibodies has been resolved, we are able to adopt the technology of the fotal sensor to calculate the concentration of the antigen. Is applicable to the whole blood test of the reactive protein C (CRP), glycosilled hemoglobin (HBA1C), urinary microalbumin (Malb), homocysteine (HCY), D-dimer, anti-stretolysis (ASO), rheumatoid factor (RF) , Homocysteine. four cardiopathy tests and five immune analyzes, etc<\/p>\n<p>Technical features<br \/>\nGlobally 3D advanced 3D nepelometry technique, real -time test on 4 channels<br \/>\nComplete blood test, completed in 1-5 min<br \/>\nIntegrated calibration, continuous temperature and quality control system, provide accurate results<br \/>\nIntelligent bubble that recognizes the technique, stable test results<br \/>\nTest channel water test function, reliable system performance<br \/>\nThe three main technologies of innovation<\/p>\n<p>Automated platform:<\/p>\n<p>Integration of multiple test methodologies<br \/>\nAutomatic laboratory platform<br \/>\nInternational reagent<\/p>\n<p>Full function module:<\/p>\n<p>Single module capable of all functions, combination of modules 1-48<br \/>\nProper laboratories for all sizes, scaling for cost savings<\/p>\n<p>3 -level calibration system:<\/p>\n<p>Physical calibration from standard fluid tracked in Ansi<br \/>\nCalibration of Standard Distance Curve<br \/>\nSystem calibration by custom quality control supplied by Bio-Rad<br \/>\nFunctions<br \/>\nFull Automatic Testing Process: Initial Temperature Discovering, Starting the Rapid Heating Mode, Reading 2D Code, Sample Mixture and R1, R2 Injection and Mixture, Test Temperature Confirmation, Methodology Confirmation, Control Calibration of quality, testing, data screen, Link connection to Lis, Report printing.<\/p>\n<p>Parameters<br \/>\nMaximum performance, minimum space space: 1nm (340-860nm); CV \uff1c 1%<br \/>\nData Interfaces: LAN, Lis\/Hi, RS232, Bluetooth, Wi-Fi, USB, SD<br \/>\nPower: AC 100 \uff5e 265V<br \/>\nVolume: l xw x h: 385 x 305 x 353mm<br \/>\nWeight: 15 kg<\/p>","protected":false},"excerpt":{"rendered":"<p>Tri Teste Brenda 360 Sekondave maksimalisht Parimi dhe zbatimi Bazohet n\u00eb reagimin specifik t\u00eb antigjenit dhe antitrupave. Reagimi i grumbullimit do t\u00eb ndodh\u00eb si kombinim i antigjenit dhe antitrupave, k\u00ebshtu rrit vler\u00ebn e shp\u00ebrndarjes s\u00eb drit\u00ebs\/ absorbimit\/ fluoreshenc\u00ebs. Duke supozuar se p\u00ebrqendrimi i antitrupave \u00ebsht\u00eb zgjidhur, ne jemi n\u00eb gjendje t\u00eb p\u00ebrvet\u00ebsojm\u00eb teknologjin\u00eb e sensorit fotelektrik p\u00ebr t\u00eb llogaritur p\u00ebrqendrimin e antigjenit. Issht\u00eb e zbatueshme p\u00ebr testin e t\u00ebr\u00eb t\u00eb gjakut t\u00eb protein\u00ebs reaktive C (CRP), hemoglobin\u00ebs glikoziluar (HbA1c), mikroalbuminit urinar (MALB), homocistein\u00ebs (HCY), D-dimer, anti-streptolizin\u00ebs (ASO), faktorit reumatoid (RF), Homocisteine. kat\u00ebr analiza t\u00eb kardiopatis\u00eb dhe pes\u00eb analiza t\u00eb imunitetit, etj Karakteristikat teknike Teknika e Nepelometris\u00eb 3D e Avancuar Globalisht 3D, Testi n\u00eb koh\u00eb reale n\u00eb 4 kanale Testimi i plot\u00eb i gjakut, i p\u00ebrfunduar n\u00eb 1-5 min Kalibrimi i integruar, temperatura e vazhdueshme dhe sistemi i kontrollit t\u00eb cil\u00ebsis\u00eb, siguroni rezultate t\u00eb sakta Bubble inteligjente q\u00eb njeh teknik\u00ebn, rezultatet e q\u00ebndrueshme t\u00eb prov\u00ebs Funksioni i prov\u00ebs s\u00eb ujit t\u00eb kanalit t\u00eb prov\u00ebs, performanca e besueshme e sistemit Tre teknologjit\u00eb kryesore t\u00eb inovacionit Platforma e automatizuar: Integrimi i metodologjive t\u00eb shum\u00ebfishta t\u00eb prov\u00ebs Platform\u00eb automatike laboratorike Reagent nd\u00ebrkomb\u00ebtar Moduli i funksionit t\u00eb plot\u00eb: Modul i vet\u00ebm i aft\u00eb p\u00ebr t\u00eb gjitha funksionet, kombinim i moduleve 1-48 Laborator\u00ebt e duhur p\u00ebr t\u00eb gjitha madh\u00ebsit\u00eb, shkall\u00ebzueshm\u00ebrin\u00eb p\u00ebr kursimet e kostos Sistemi i kalibrimit me 3 nivele: Kalibrimi fizik nga l\u00ebngu standard i gjurmuar n\u00eb ANSI Kalibrimi i kurb\u00ebs standarde n\u00eb distanc\u00eb Kalibrimi i sistemit sipas kontrollit t\u00eb cil\u00ebsis\u00eb me porosi t\u00eb furnizuar nga Bio-Rad Funksione Procesi i plot\u00eb i testimit automatik: Zbulimi fillestar i temperatur\u00ebs, fillimi i m\u00ebnyr\u00ebs s\u00eb shpejt\u00eb t\u00eb ngrohjes, leximi i kodit 2D, p\u00ebrzierja e mostr\u00ebs dhe R1, injeksioni i R2 dhe p\u00ebrzierja, konfirmimi i temperatur\u00ebs s\u00eb prov\u00ebs, konfirmimi i metodologjis\u00eb, kalibrimi i kontrollit t\u00eb cil\u00ebsis\u00eb, testimi, ekrani i t\u00eb dh\u00ebnave, lidhja me lidhjen me t\u00eb Lis, Raporto Shtypje. Parametra Performanca maksimale, hap\u00ebsira hap\u00ebsinore minimale: 1nm (340-860nm); CV \uff1c 1% Nd\u00ebrfaqet e t\u00eb dh\u00ebnave: LAN, LIS\/HI, RS232, Bluetooth, Wi-Fi, USB, SD Fuqia: AC 100 \uff5e 265V V\u00ebllimi: L XW X H: 385 x 305 x 353mm Pesha: 15 kg<\/p>","protected":false},"author":1,"featured_media":990,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[23],"tags":[],"class_list":["post-334","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-sistemi-autoimun"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/posts\/334","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/comments?post=334"}],"version-history":[{"count":8,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/posts\/334\/revisions"}],"predecessor-version":[{"id":1103,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/posts\/334\/revisions\/1103"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/media\/990"}],"wp:attachment":[{"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/media?parent=334"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/categories?post=334"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/tags?post=334"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}