{"id":1388,"date":"2024-03-05T14:14:45","date_gmt":"2024-03-05T14:14:45","guid":{"rendered":"https:\/\/www.atommed.net\/web\/?p=1388"},"modified":"2024-03-05T14:15:57","modified_gmt":"2024-03-05T14:15:57","slug":"dxm-microscan-walkaway-id-ast-system","status":"publish","type":"post","link":"https:\/\/www.atommed.net\/web\/en\/2024\/03\/05\/dxm-microscan-walkaway-id-ast-system\/","title":{"rendered":"DxM MicroScan WalkAway ID\/AST System"},"content":{"rendered":"<table class=\"ui very basic collapsing celled table\">\n<tbody>\n<tr>\n<td>\n<h4 class=\"ui image header\" role=\"heading\" data-uw-rm-heading=\"level\" aria-level=\"3\">Physical<\/h4>\n<\/td>\n<td>\n<ul>\n<li>DxM 1040 MicroScan WalkAway: 29&#8243; H x 38.5&#8243; W x 34&#8243; D; 376 lbs<\/li>\n<li>DxM 1096 MicroScan WalkAway: 37&#8243; H x 38.5&#8243; W x 34&#8243; D; 410 lbs<\/li>\n<li>Color: White with gray trim<\/li>\n<li>Interface connector: RJ-45 carrying RS-232 protocol<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Power Requirements<\/h4>\n<\/td>\n<td>\n<ul>\n<li>Line voltage: 100\/120\/220\/230\/240 VAC selected by internal jumpers<\/li>\n<li>Line frequency: 50\/60 Hz \u00b15%<\/li>\n<li>Line current:\n<ul>\n<li>9 A (nominal), 11 A (maximum) for 100\/120 VAC operation<\/li>\n<li>4.5 A (nominal), 5.5 A (maximum) for 220\/230\/240 VAC operation<\/li>\n<\/ul>\n<\/li>\n<li>Power loss protection: Circuitry provided to ensure fail-safe operation; power interruption will not result in a hazard; automatic restart<\/li>\n<li>Heat generation: 3,400 BTU\/hour<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Recommended Laboratory Environmental Conditions<\/h4>\n<\/td>\n<td>\n<ul>\n<li>Temperature: (operating) 59\u00b0F to 80.6\u00b0F<\/li>\n<li>Humidity: 30% to 80% RH (no condensation)<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Safety Requirements<\/h4>\n<\/td>\n<td>\n<ul>\n<li>Ground impedance: 0.1 \u03a9 (maximum)<\/li>\n<li>Dielectric withstand voltage: No dielectric breakdown (at 1,400 VDC for one minute)<\/li>\n<li>Leakage current: &lt;0.5 mA<\/li>\n<li>Removable power cord:\n<ul>\n<li>3-conductor, 14 AWG (100\/120 V)<\/li>\n<li>3-conductor, 16 AWG (220\/230\/240 V)<\/li>\n<\/ul>\n<\/li>\n<li>Interlocks: Provided on panel access door, reagent dispense drawer and service hatch<\/li>\n<li>Power plug: NEMA type 5-15P\/IEC 60320 type C14<\/li>\n<li>Standards: Certified to conform to IEC 61010-1: 2010 (3rd Edition), EN 61010-1: 2010 (3rd Edition), CAN\/CSA C22.2 No. 61010-1-12, UL 61010-1 (3rd Edition), IEC 61010-2-081: 2015, EN 61010-2-081: 2015, CAN\/CSA C22.2 No. 61010-2-081:15, UL 61010-2-081: 2015, IEC 61010-2-101: 2015, EN 61010-2-101: 2017, CAN\/CSA C22.2 No. 61010-2-101:15, UL 61010-2-101: 2015<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Overcurrent Protection<\/h4>\n<\/td>\n<td>\n<ul>\n<li>Fusing: Primary fuses F1 and F2, IEC (5&#215;20 mm size) time lag\/slow blow type, 250 V rated, 12 A (100\/120 V)\/ 6.3 A (220\/230\/240 V)<\/li>\n<li>Light source:\n<ul>\n<li>Tungsten-halogen lamp, 50 W, 12 V<\/li>\n<li>Tungsten-halogen lamp, TL 21\u20442, 15 W, 10.5 V<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Display<\/h4>\n<\/td>\n<td>2-line, 20-character alphanumeric vacuum fluorescence display<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Temperature Control<\/h4>\n<\/td>\n<td>Set by computer at 35\u00b0C \u00b11\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Bar Code<\/h4>\n<\/td>\n<td>Code 39 standard conformance<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Performance<\/h4>\n<\/td>\n<td>\n<ul>\n<li>Panel capacity for DxM 1040 MicroScan WalkAway System: 40 MicroScan panels with 96 wells each of any type compatible with the incubator environment; up to eight panel towers with five panels each<\/li>\n<li>Panel capacity for DxM 1096 MicroScan WalkAway System: 96 MicroScan panels with 96 wells each of any type compatible with the incubator environment; up to eight panel towers with 12 panels each<\/li>\n<li>Incubation temperature stability: \u00b11\u00b0C<\/li>\n<li>Reagent type capacity: 10 reagents total<\/li>\n<li>Reagent dispense volume (\u03bcl): 15 to 90, depending on reagent dispensed<\/li>\n<li>Oil dispense volume (\u03bcl): 60 to 150<\/li>\n<li>Operator interface: Front-panel controls and PC keyboard, monitor and LabPro software<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Physical DxM 1040 MicroScan WalkAway: 29&#8243; H x 38.5&#8243; W x 34&#8243; D; 376 lbs DxM 1096 MicroScan WalkAway: 37&#8243; H x 38.5&#8243; W x 34&#8243; D; 410 lbs Color: White with gray trim Interface connector: RJ-45 carrying RS-232 protocol Power Requirements Line voltage: 100\/120\/220\/230\/240 VAC selected by internal jumpers Line frequency: 50\/60 Hz \u00b15% Line current: 9 A (nominal), 11 A (maximum) for 100\/120 VAC operation 4.5 A (nominal), 5.5 A (maximum) for 220\/230\/240 VAC operation Power loss protection: Circuitry provided to ensure fail-safe operation; power interruption will not result in a hazard; automatic restart Heat generation: 3,400 BTU\/hour Recommended Laboratory Environmental Conditions Temperature: (operating) 59\u00b0F to 80.6\u00b0F Humidity: 30% to 80% RH (no condensation) Safety Requirements Ground impedance: 0.1 \u03a9 (maximum) Dielectric withstand voltage: No dielectric breakdown (at 1,400 VDC for one minute) Leakage current: &lt;0.5 mA Removable power cord: 3-conductor, 14 AWG (100\/120 V) 3-conductor, 16 AWG (220\/230\/240 V) Interlocks: Provided on panel access door, reagent dispense drawer and service hatch Power plug: NEMA type 5-15P\/IEC 60320 type C14 Standards: Certified to conform to IEC 61010-1: 2010 (3rd Edition), EN 61010-1: 2010 (3rd Edition), CAN\/CSA C22.2 No. 61010-1-12, UL 61010-1 (3rd Edition), IEC 61010-2-081: 2015, EN 61010-2-081: 2015, CAN\/CSA C22.2 No. 61010-2-081:15, UL 61010-2-081: 2015, IEC 61010-2-101: 2015, EN 61010-2-101: 2017, CAN\/CSA C22.2 No. 61010-2-101:15, UL 61010-2-101: 2015 Overcurrent Protection Fusing: Primary fuses F1 and F2, IEC (5&#215;20 mm size) time lag\/slow blow type, 250 V rated, 12 A (100\/120 V)\/ 6.3 A (220\/230\/240 V) Light source: Tungsten-halogen lamp, 50 W, 12 V Tungsten-halogen lamp, TL 21\u20442, 15 W, 10.5 V Display 2-line, 20-character alphanumeric vacuum fluorescence display Temperature Control Set by computer at 35\u00b0C \u00b11\u00b0C Bar Code Code 39 standard conformance Performance Panel capacity for DxM 1040 MicroScan WalkAway System: 40 MicroScan panels with 96 wells each of any type compatible with the incubator environment; up to eight panel towers with five panels each Panel capacity for DxM 1096 MicroScan WalkAway System: 96 MicroScan panels with 96 wells each of any type compatible with the incubator environment; up to eight panel towers with 12 panels each Incubation temperature stability: \u00b11\u00b0C Reagent type capacity: 10 reagents total Reagent dispense volume (\u03bcl): 15 to 90, depending on reagent dispensed Oil dispense volume (\u03bcl): 60 to 150 Operator interface: Front-panel controls and PC keyboard, monitor and LabPro software<\/p>","protected":false},"author":2,"featured_media":1389,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[61],"tags":[],"class_list":["post-1388","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-beckman-coulter"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/posts\/1388","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/comments?post=1388"}],"version-history":[{"count":1,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/posts\/1388\/revisions"}],"predecessor-version":[{"id":1390,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/posts\/1388\/revisions\/1390"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/media\/1389"}],"wp:attachment":[{"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/media?parent=1388"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/categories?post=1388"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/tags?post=1388"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}