{"id":1379,"date":"2024-03-05T14:03:32","date_gmt":"2024-03-05T14:03:32","guid":{"rendered":"https:\/\/www.atommed.net\/web\/?p=1379"},"modified":"2024-03-05T14:03:37","modified_gmt":"2024-03-05T14:03:37","slug":"dxh-900-hematology-analyzer","status":"publish","type":"post","link":"https:\/\/www.atommed.net\/web\/en\/2024\/03\/05\/dxh-900-hematology-analyzer\/","title":{"rendered":"DxH 900 Hematology Analyzer"},"content":{"rendered":"<table class=\"ui very basic collapsing celled table\">\n<tbody>\n<tr>\n<td>\n<h4 class=\"ui image header\" role=\"heading\" data-uw-rm-heading=\"level\" aria-level=\"3\">Available Test Menu<\/h4>\n<\/td>\n<td>\n<ul>\n<li>CBC: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV<\/li>\n<li>Differential: NE, LY, MO, EO, BA, NRBC, NE#, LY#, MO#, EO#, BA#, NRBC#<\/li>\n<li>Reticulocytes: RET, RET#, MRV, IRF<\/li>\n<li><a href=\"https:\/\/www.beckmancoulter.com\/en\/products\/hematology\/early-sepsis-indicator\">Monocyte Distribution Width<\/a>\u00a0(MDW) (when enabled)<\/li>\n<li>Body fluids (spinal, serous and synovial): TNC, RBC, Pleural, Pericardial, Peritoneal<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Throughput<\/h4>\n<\/td>\n<td>Up to 100 samples\/hour<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Reagents<\/h4>\n<\/td>\n<td>4 required reagents; environmentally friendly methanol- and ethylene glycol-free<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Sample Volumes<\/h4>\n<\/td>\n<td>165 \u03bcL aspiration volume; 0.5 ml dead volume<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Power<\/h4>\n<\/td>\n<td>\n<ul>\n<li>Redundant power computers in a workcell<\/li>\n<li>90\u2013264 VAC and 48\u201362 Hz<\/li>\n<li>DxH 900 SPM: 520 W<\/li>\n<li>DxH standard computer: 160 W<\/li>\n<li>Monitor: 35 W<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Whole Blood Performance\u2014Measuring Range<\/h4>\n<\/td>\n<td>\n<table>\n<tbody>\n<tr>\n<td>Parameter<\/td>\n<td>\u00a0Units<\/td>\n<td>\u00a0Analytical Measuring Range<\/td>\n<\/tr>\n<tr>\n<td>\u00a0WBC<\/td>\n<td>\u00a0x10<sup>3<\/sup>\u00a0cells\/\u03bcL<\/td>\n<td>0.050\u20132.000<br role=\"presentation\" data-uw-rm-sr=\"\" \/>&gt;2.000\u2013100.000<br role=\"presentation\" data-uw-rm-sr=\"\" \/>&gt;100.000\u2013400.000<\/td>\n<\/tr>\n<tr>\n<td>\u00a0RBC<\/td>\n<td>\u00a0x10<sup>6<\/sup>\u00a0cells\/\u03bcL<\/td>\n<td>\u00a00.005\u20138.500<\/td>\n<\/tr>\n<tr>\n<td>\u00a0HGB<\/td>\n<td>\u00a0g\/dL<\/td>\n<td>\u00a00.10\u201325.50<\/td>\n<\/tr>\n<tr>\n<td>\u00a0MCV<\/td>\n<td>\u00a0fL<\/td>\n<td>50.00\u2013150.00<\/td>\n<\/tr>\n<tr>\n<td>\u00a0RDW<\/td>\n<td>\u00a0%<\/td>\n<td>\u00a010.00\u201340.00<\/td>\n<\/tr>\n<tr>\n<td>\u00a0RDW-SD<\/td>\n<td>\u00a0fL<\/td>\n<td>\u00a015.00\u2013150.00<\/td>\n<\/tr>\n<tr>\n<td>\u00a0PLT<\/td>\n<td>\u00a0x10<sup>3<\/sup>\u00a0cells\/\u03bcL<\/td>\n<td>\u00a03.0\u20133000.0<\/td>\n<\/tr>\n<tr>\n<td>\u00a0MPV<\/td>\n<td>\u00a0fL<\/td>\n<td>\u00a05.00\u201325.00<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Data Management<\/h4>\n<\/td>\n<td>\n<ul>\n<li>50,000 patient results with graphics for standalone<\/li>\n<li>100,000 patient results with graphics for power computer<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Quality Assurance<\/h4>\n<\/td>\n<td>QC with Levy-Jennings graph; XB\/XM for moving averages, daily check, intelligent quality monitoring, MRV, IRF, customizable calibration and QC reminders and alerts, auto export of QC<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Sample Transport Capabilities<\/h4>\n<\/td>\n<td>\n<ul>\n<li>Capacity: 20 five-tube cassettes<\/li>\n<li>Bar codes: digital bar code with 2D bar code capability<\/li>\n<li>Sample ID: up to 22 characters<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Reliability<\/h4>\n<\/td>\n<td>\u00a0PROService remote management system: maximum uptime with walk-away troubleshooting and preemptive alerts of instrument issues<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Weight and Dimensions<\/h4>\n<\/td>\n<td>\n<ul>\n<li>Width: 75.57 cm<\/li>\n<li>Height: 174 cm, cover closed; 194 cm, cover lifted<\/li>\n<li>Depth: 82.80 cm, including removable back panel; 79.25 cm, excluding removable back panel<\/li>\n<li>Weight:\u00a0254 kg (560 lbs)<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<h4 class=\"ui image header\">Additional Clearance<\/h4>\n<\/td>\n<td>3.8 cm behind instrument for sufficient cooling; 15.2 cm per side of instrument for troubleshooting<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Available Test Menu CBC: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV Differential: NE, LY, MO, EO, BA, NRBC, NE#, LY#, MO#, EO#, BA#, NRBC# Reticulocytes: RET, RET#, MRV, IRF Monocyte Distribution Width\u00a0(MDW) (when enabled) Body fluids (spinal, serous and synovial): TNC, RBC, Pleural, Pericardial, Peritoneal Throughput Up to 100 samples\/hour Reagents 4 required reagents; environmentally friendly methanol- and ethylene glycol-free Sample Volumes 165 \u03bcL aspiration volume; 0.5 ml dead volume Power Redundant power computers in a workcell 90\u2013264 VAC and 48\u201362 Hz DxH 900 SPM: 520 W DxH standard computer: 160 W Monitor: 35 W Whole Blood Performance\u2014Measuring Range Parameter \u00a0Units \u00a0Analytical Measuring Range \u00a0WBC \u00a0x103\u00a0cells\/\u03bcL 0.050\u20132.000&gt;2.000\u2013100.000&gt;100.000\u2013400.000 \u00a0RBC \u00a0x106\u00a0cells\/\u03bcL \u00a00.005\u20138.500 \u00a0HGB \u00a0g\/dL \u00a00.10\u201325.50 \u00a0MCV \u00a0fL 50.00\u2013150.00 \u00a0RDW \u00a0% \u00a010.00\u201340.00 \u00a0RDW-SD \u00a0fL \u00a015.00\u2013150.00 \u00a0PLT \u00a0x103\u00a0cells\/\u03bcL \u00a03.0\u20133000.0 \u00a0MPV \u00a0fL \u00a05.00\u201325.00 Data Management 50,000 patient results with graphics for standalone 100,000 patient results with graphics for power computer Quality Assurance QC with Levy-Jennings graph; XB\/XM for moving averages, daily check, intelligent quality monitoring, MRV, IRF, customizable calibration and QC reminders and alerts, auto export of QC Sample Transport Capabilities Capacity: 20 five-tube cassettes Bar codes: digital bar code with 2D bar code capability Sample ID: up to 22 characters Reliability \u00a0PROService remote management system: maximum uptime with walk-away troubleshooting and preemptive alerts of instrument issues Weight and Dimensions Width: 75.57 cm Height: 174 cm, cover closed; 194 cm, cover lifted Depth: 82.80 cm, including removable back panel; 79.25 cm, excluding removable back panel Weight:\u00a0254 kg (560 lbs) Additional Clearance 3.8 cm behind instrument for sufficient cooling; 15.2 cm per side of instrument for troubleshooting<\/p>","protected":false},"author":2,"featured_media":1380,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[61],"tags":[],"class_list":["post-1379","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-beckman-coulter"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/posts\/1379","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/comments?post=1379"}],"version-history":[{"count":1,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/posts\/1379\/revisions"}],"predecessor-version":[{"id":1381,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/posts\/1379\/revisions\/1381"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/media\/1380"}],"wp:attachment":[{"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/media?parent=1379"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/categories?post=1379"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.atommed.net\/web\/en\/wp-json\/wp\/v2\/tags?post=1379"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}